Laser Pulses Damage Pig Retinas at Permitted Levels
A 2026 study found short near-infrared laser pulses within relaxed ANSI limits caused retinal lesions in Yucatan mini pigs.
Updated on Nov. 12, 2026 in Veterinary Medicine

Researchers led by Peralta et al. reported that single 100-femtosecond laser pulses above 1300 nanometers produced small retinal lesions in Yucatan mini pigs even at exposure levels permitted under ANSI's 2022 update. The findings, published in the Journal of Laser Applications, challenge whether the relaxed safety guidelines are sufficient.
Why it matters
The study suggests the current maximum permissible exposure guidelines for ultrashort-pulse lasers may not protect eyes adequately. Because the swine retina is less sensitive to laser damage than the human retina, researchers warn that any threshold based on the pig model would likely underestimate human risk.
The study used single 100-femtosecond near-infrared pulses at wavelengths above 1300 nanometers, a range the researchers say should be modified in ANSI's standards for pulse durations under 10 picoseconds. Whether these lesions would occur at the same thresholds in human eyes has not been established.
The players
ANSI (American National Standards Institute)
ANSI is a U.S.-based nonprofit that coordinates voluntary consensus standards, including the laser safety criteria updated in 2022.
Peralta et al.
The research team whose study measured retinal damage in Yucatan mini pigs exposed to ultrashort-pulse lasers and published the findings in 2026.
The details
Researchers measured retinal damage in Yucatan mini pigs exposed to lasers within the parameters ANSI relaxed in 2022. The lesions appeared as small spots, and the pig retinas could not withstand the current guideline levels, prompting the team to recommend revisions for lasers between 1300 and 1400 nanometers.
Timeline
2022: ANSI relaxed maximum permissible exposure guidelines for short laser pulses.
2026: Peralta et al. study published in the Journal of Laser Applications.
Veterinary Medicine Context
The findings sit against ANSI's 2022 relaxation of exposure limits for 1200 to 1400 nanometer lasers, which this study argues was set without adequate biological testing. Because the Yucatan mini pig is used as a model for the eye, the results add pressure on standards bodies to revisit limits for these wavelengths.
Anyone working with or near ultrashort-pulse lasers in research, surgery, or manufacturing may see future safety guidance change. The study indicates current exposure allowances may not fully protect eyes, so cautious handling remains important.
The takeaway
Safety standards for new laser technologies depend on animal data that may not match human biology. Readers who work with these lasers should follow current protective practices until guidelines are formally revised.
Further reading
Explore more on Veterinary Medicine to see how animal models shape safety research.
More information
Read the full Peralta et al. retinal damage study in the Journal of Laser Applications.
Source note: This article includes information reported by American Institute of Physics.