comemso Launches Portable AC Charger Tester
The Easy Chester Micro combines an installation tester and an adapter box in one 5.4 kg case for checking AC wall boxes and charging stations.
Updated on Nov. 9, 2026 in Electric Vehicles

German company comemso has launched the Easy Chester Micro, a portable tester for AC wall boxes and charging stations. The device simulates a vehicle to IEC 61851-1 and SAE J1772 and can set up ISO 15118-2 communication without an external protocol converter.
Why it matters
Since January 8, 2026, the EU's AFIR regulation has required new or renovated public charging points to comply with EN ISO 15118-1 to -5. Tools that verify charging communication and safety on site can help operators and installers meet those requirements.
The 5.4 kg case is rated IP 66 when closed and includes a 10.1-inch touchscreen. The device runs insulation resistance tests at 250 V to 1,000 V and residual-current device tests from 6 mA to 300 mA, but it does not support TLS-secured charging sessions.
The players
comemso
A German company that develops electric vehicle charging test and installation equipment.
The details
The tester measures Control Pilot voltage, PWM duty cycle and Proximity Pilot values through a Type 1 or Type 2 AC inlet. Its ISO 15118-2 test checks the station's powerline communication chip and PLC link, and the test report records the SLAC connection setup, attenuation value and PLC MAC address.
Timeline
January 8, 2026: AFIR compliance requirement for public charging points took effect.
First quarter of 2027: Planned support for ISO 15118-20 is expected.
Roadmap
AFIR's January 8, 2026 requirement that public charging points comply with EN ISO 15118-1 to -5 pushes operators toward standardized vehicle-to-charger communication. Testers like the Easy Chester Micro that verify ISO 15118-2 links on site reflect that shift toward plug-and-charge interoperability.
Installers and operators of public AC charging points can use the tester to check safety and communication before commissioning a station. Drivers benefit indirectly when chargers can authenticate sessions and set up ISO 15118-2 communication reliably.
The takeaway
Standards-based testing on site can catch communication and safety faults before a charger goes into service. Operators planning AFIR-compliant upgrades should verify charging communication early in the installation process.
Further reading
Explore more on Electric Vehicles for context on charging infrastructure standards and tools.