Broadcom Patches Critical VMware vCenter Authentication Flaw
The CVSS 9.8 vulnerability lets network-based attackers bypass authentication, and Broadcom lists no workaround.
Updated on Nov. 19, 2026 in Cybersecurity

Broadcom disclosed a critical authentication bypass vulnerability in VMware vCenter, tracked as CVE-2026-123890, and released fixed versions for all supported branches. The flaw, located in the VMware Directory Service, is present in vCenter 8.0, 9.0, and 9.1 and was reported by Mandiant.
Why it matters
The flaw allows an attacker with network access to bypass authentication on a platform used to manage virtualized infrastructure, making timely patching the primary defense. Broadcom has reported no attacks exploiting it and has published no public exploit code.
The advisory assigns the authentication bypass a CVSS score of 9.8 and places four further flaws between 6.7 and 8.1, all within the VMware Directory Service. Broadcom has not disclosed whether any attacker has attempted to use these flaws against live systems.
The players
Broadcom
Broadcom is a global semiconductor and infrastructure software company that owns VMware and issued the vCenter security advisory.
Mandiant
Mandiant is a cybersecurity firm owned by Google that reported the vCenter authentication bypass to Broadcom.
The details
The updates are cumulative and cannot be installed through vCenter Quick Patch, and virtual machines continue running while vCenter installs the update, though management access drops briefly. Broadcom lists no workaround, so the fixed versions are the only remediation it has published.
Timeline
- November 19, 2026: Broadcom published the advisory disclosing CVE-2026-123890.
- October 2025: vSphere 7.0 left general support.
The Tech Race
The disclosure follows earlier vCenter patches, including CVE-2026-59309, and comes after August attacks against a separate vCenter flaw, CVE-2026-59310, that compromised 361 IP addresses across 47 countries. Each round of fixes adds to a pattern of recurring critical flaws in the platform that enterprises use to run their virtualized infrastructure.
Administrators running vCenter 8.0, 9.0, or 9.1 need to apply the fixed versions, since no workaround exists and the updates cannot be installed through Quick Patch. Because management access drops briefly during installation while virtual machines keep running, teams should plan the update outside peak operating windows.
The takeaway
Organizations running vCenter should treat this advisory as urgent, apply the fixed versions across every supported branch, and confirm that management access is restored after the brief outage during installation.
Further reading
For more on how such flaws are tracked and fixed across the industry, see the Cybersecurity section.